Commit 7aba438f authored by Tobias Maile's avatar Tobias Maile

removing the parent system attribute from the parent system, submitting the...

removing the parent system attribute from the parent system, submitting the corrected version of simxml
parent 08ba4cc3
......@@ -283,7 +283,6 @@ System;"";"";"";"";
Maintenance Level;"";"";"IfcSystem.Pset_ServiceLifeFactors.MaintenanceLevel";"";
Members;"";"";"GlobalId.HasAssignments.IfcRelAssignsToGroup.RelatedObjects";"SimObject.simcore:GroupMembers";
Outdoor Environment;"";"";"IfcSystem.Pset_ServiceLifeFactors.OutdoorEnvironment";"";
ParentSystem;"";"1:1";"GlobalId.RelatingGroup.IfcRelAggregates.RelatedObjects.IfcSystem";"SimSystem.simbldg:ParentSystem";
Quality Of Components;"";"";"IfcSystem.Pset_ServiceLifeFactors.QualityOfComponents";"";
SimModelName;"";"1:1";"IfcSystem.Name";"SimSystem.simcore:SimModelName";
SimModelSubtype;"";"1:1,IfcSystem.###.###.ObjectType.DS_HEATING";"IfcSystem.###.###.FullSystem";"SimSystem.simcore:SimModelSubtype";
......@@ -412,8 +411,8 @@ Valve;"[R] Maybe tempering valve is more specific...on SimModel side?";"- ";"";"
Finish;"";"";"IfcValve.Pset_ValveTypeFaucet.Finish";"";
Flow Coefficient;"";"";"IfcValve.Pset_ValveTypeCommon.FlowCoefficient";"";
Flushing Rate;"";"";"IfcValve.Pset_ValveTypeFlushing.FlushingRate";"";
Has Hose Union;"";"";"IfcValve.Pset_ValveTypeDrawOffCock.HasHoseUnion";"";
Has Hose Union;"";"";"IfcValve.Pset_ValveTypeGasTap.HasHoseUnion";"";
Has Hose Union;"";"";"IfcValve.Pset_ValveTypeDrawOffCock.HasHoseUnion";"";
Has Integral Shut Off Device;"";"";"IfcValve.Pset_ValveTypeFlushing.HasIntegralShutOffDevice";"";
Is Automatic;"";"";"IfcValve.Pset_ValveTypeAirRelease.IsAutomatic";"";
Is High Pressure;"";"";"IfcValve.Pset_ValveTypeFlushing.IsHighPressure";"";
......@@ -459,8 +458,8 @@ Valve;"[R] Maybe tempering valve is more specific...on SimModel side?";"- ";"";"
Finish;"";"";"IfcValve.Pset_ValveTypeFaucet.Finish";"";
Flow Coefficient;"";"";"IfcValve.Pset_ValveTypeCommon.FlowCoefficient";"";
Flushing Rate;"";"";"IfcValve.Pset_ValveTypeFlushing.FlushingRate";"";
Has Hose Union;"";"";"IfcValve.Pset_ValveTypeGasTap.HasHoseUnion";"";
Has Hose Union;"";"";"IfcValve.Pset_ValveTypeDrawOffCock.HasHoseUnion";"";
Has Hose Union;"";"";"IfcValve.Pset_ValveTypeGasTap.HasHoseUnion";"";
Has Integral Shut Off Device;"";"";"IfcValve.Pset_ValveTypeFlushing.HasIntegralShutOffDevice";"";
Is Automatic;"";"";"IfcValve.Pset_ValveTypeAirRelease.IsAutomatic";"";
Is High Pressure;"";"";"IfcValve.Pset_ValveTypeFlushing.IsHighPressure";"";
......@@ -506,8 +505,8 @@ Valve;"[R] Maybe tempering valve is more specific...on SimModel side?";"- ";"";"
Finish;"";"";"IfcValve.Pset_ValveTypeFaucet.Finish";"";
Flow Coefficient;"";"";"IfcValve.Pset_ValveTypeCommon.FlowCoefficient";"";
Flushing Rate;"";"";"IfcValve.Pset_ValveTypeFlushing.FlushingRate";"";
Has Hose Union;"";"";"IfcValve.Pset_ValveTypeGasTap.HasHoseUnion";"";
Has Hose Union;"";"";"IfcValve.Pset_ValveTypeDrawOffCock.HasHoseUnion";"";
Has Hose Union;"";"";"IfcValve.Pset_ValveTypeGasTap.HasHoseUnion";"";
Has Integral Shut Off Device;"";"";"IfcValve.Pset_ValveTypeFlushing.HasIntegralShutOffDevice";"";
Is Automatic;"";"";"IfcValve.Pset_ValveTypeAirRelease.IsAutomatic";"";
Is High Pressure;"";"";"IfcValve.Pset_ValveTypeFlushing.IsHighPressure";"";
......
Markdown is supported