Commit 45b03861 authored by Tobias Maile's avatar Tobias Maile

sebastians latest changes

parent deaac9c7
......@@ -34,23 +34,24 @@ Pipe Segment;"[T] Assuming indoor pipes for now";"1:1";"IfcPipeSegment";"SimFlow
Boiler;"KIT_20151030: removed the general 'Properties for Boiler'- now only the specific Properties of WaterBoiler exist.";"-";"-";"-";
WaterBoiler;"";"1:1,IfcBoiler.PredefinedType.WATER";"IfcBoiler";"SimFlowPlant_Boiler_BoilerHotWater";
Properties for Boiler;"";"";"-";"";
Curve A0;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A0";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coef1Constant";
Curve A1;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A1";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coef_2_X";
Curve A2;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A2";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coef_3_X_2";
Curve A3;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A3";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coef_4_Y";
Curve A4;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A4";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coeff5_Y_2";
Curve A5;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A5";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coeff6_X_y";
Curve A6;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A6";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coeff7_X_3";
Curve A7;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A7";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coeff8_Y_3";
Curve A8;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A8";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coeff9_X_2_Y";
Curve A9;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A9";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_Coeff10_X_y_2";
Curve Maximum Output;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MaximumOutput";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_MaxCurveOutput";
Curve Maximum X;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MaximumX";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_MaxValX";
Curve Maximum Y;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MaximumY";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_MaxValY";
Curve Miminum Output;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MinimumOutput";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_MinCurveOutput";
Curve Minimum X;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MinimumX";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_MinValX";
Curve Minimum Y;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MinimumY";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName.SimPerfCurve_MinValY";
CurveTricker;"";"";"IfcBoiler.Pset_BoilerTypeCommon.GlobalId";"SimPerfCurve_Mathematical_Bicubic";
KindOfCurve;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.GlobalId";"SimFlowPlant.simgeom:SimPerformanceCurve_Mathematical_Quadratic";
Curve A0;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A0";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coef1Constant";
Curve A1;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A1";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coef_2_X";
Curve A2;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A2";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coef_3_X_2";
Curve A3;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A3";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coef_4_Y";
Curve A4;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A4";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coeff5_Y_2";
Curve A5;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A5";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coeff6_X_y";
Curve A6;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A6";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coeff7_X_3";
Curve A7;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A7";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coeff8_Y_3";
Curve A8;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A8";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coeff9_X_2_Y";
Curve A9;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.Coeff_A9";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_Coeff10_X_y_2";
Curve Maximum Output;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MaximumOutput";"SimFlowPlant_NrmlizedBoilerEffCurveName.simgeom:SimPerfCurve_MaxCurveOutput";
Curve Maximum X;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MaximumX";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_MaxValX";
Curve Maximum Y;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MaximumY";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_MaxValY";
Curve Miminum Output;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MinimumOutput";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_MinCurveOutput";
Curve Minimum X;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MinimumX";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_MinValX";
Curve Minimum Y;"";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves.MinimumY";"SimPerformanceCurve_Mathematical_Quadratic.simgeom:SimPerfCurve_MinValY";
Boiler Curve Reference;"Note: this element to the boiler object is generated if a curve property (Ifc_ComplexProperty ) is present in ifc model.";"1:1";"IfcBoiler.Pset_BoilerTypeCommon.PartialLoadEfficiencyCurves";"SimFlowPlant.simmep:SimFlowPlant_NrmlizedBoilerEffCurveName";
Energy Source - Coal;"";"Enum";"IfcBoiler.Pset_BoilerTypeCommon.EnergySource.COAL";"SimFlowPlant.simmep:SimFlowPlant_FuelType.Coal";
Energy Source - Electricity;"";"Enum";"IfcBoiler.Pset_BoilerTypeCommon.EnergySource.ELECTRICITY";"SimFlowPlant.simmep:SimFlowPlant_FuelType.Electricity";
Energy Source - Gas;"";"Enum";"IfcBoiler.Pset_BoilerTypeCommon.EnergySource.GAS";"SimFlowPlant.simmep:SimFlowPlant_FuelType.NaturalGas";
......@@ -483,7 +484,7 @@ Valve;"[R] Maybe tempering valve is more specific...on SimModel side?";"- ";"";"
ControllerVariable.Flow;"";"Enum";"IfcValve.PSim_Controller.ControllerVariable.FLOW";"SimController_Default_Default";
ControllerVariable.StorageEnergy;"";"Enum";"IfcValve.PSim_Controller.ControllerVariable.STORAGEENERGY";"SimController_ThermalStorage_ThermalEnergyStorageTank";
ControllerVariable.Temperature;"";"Enum";"IfcValve.PSim_Controller.ControllerVariable.TEMPERATURE";"SimController_SupplyWater_Temperature";
KindOfController;"";"";"IfcValve.PSim_Controller.GlobalId";"SimController_SupplyWater_Temperature";
KindOfController;"";"";"IfcValve.PSim_Controller.GlobalId";"SimFlowPlant.simmep:SimController_SupplyWater_Temperature";
MeasuredVariable;"";"1:1";"IfcValve.PSim_Controller.MeasuredVariable";"SimController.simmep:MeasuredVariable";
ScheduledSetpointValue;"";"1:1";"IfcValve.PSim_Controller.ScheduledSetpointValue";"SimController.simmep:ScheduledSetpointValue";
Properties for Valve;"[R] How do we handle the valve properties?";"";"IfcSystem.Pset_ServiceLifeFactors";"";
......